TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Level System

TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Level System

Product Number: LXV322.99.00002

Price: Contact Us
Talk to an Expert

TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Blanket Level Instrument

Compact instrument for analytical determination by continuous measurement mode with integration time setting.
Adjustment of up to 5 measuring points, storage of measuring values with name, date and time. Shockproof.
Combined multiple beam alternating light method with infrared diode system and beam focusing; wavelength 860 nm. The measurement ranges for turbidity and suspended solids are: 0.001 - 9999 FNU and 0.001 - 400 g/L respectively.

Applications:

  • Municipal Water

Benefits

Three Parameters in One Instrument

The Hach TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Blanket Level Instrument's unique multi-beam alternating light method with infrared diode system gives it a broad measuring range for both turbidity and suspended solids in one portable handheld instrument.

Multiple Calibration Curves for Convenience

It stores up to four different calibration curves for suspended solids and one for turbidity. There's no need for constant re-calibration for different locations or types of sludge.

Easy Sludge Blanket Levels

The sludge blanket level can be measured by setting the units to mg/L, g/L or percent. Calibrate the instrument and then slowly lower the sensor into the clarifier. The suspended solids concentration will significantly increase as it reaches the sludge blanket level. Once the blanket level is reached, examine the sensor cable which is marked every meter to determine the sludge blanket level depth from the water surface.

Air Bubble Compensation for Accuracy

The instrument software automatically compensates for air bubbles to prevent its influence on the measurement. Turbidity is pre-calibrated with a calibration curve stored in the instrument. For suspended solids, each of the calibration curves can be closely adjusted to the laboratory results because each calibration curve can use up to three points per curve plus a zero value.

Durable Materials for Long Life

The probe is made of polished stainless steel with a scratch-resistant sapphire window to withstand harsh environments. Polished stainless steel helps keep particles from sticking to the surface of the probe. The internal memory stores up to 290 measuring values, including time, date, measurement, location, and homogeneity. Three operating modes are available: single, interval, or continuous.

Rechargeable Battery Power

With rechargeable batteries, the Hach TSS Portable Hand-held Turbidity, Suspended Solids, and Sludge Blanket Level Instrument can provide up to one month of usage in typical measuring mode and up to four hours of continuous operation. Interval mode has automatic shut off between measurements for longer operation in the field. The battery status is always visible. The operating menu is user-friendly and is displayed on an easy-to-read LCD graphic display.

Loading

Label Definitions*


Product Life Cycle

*when applicable

Phase Out

Items with this label are at the end of their life cycle and may become obsolete in the future.

Obsolete

Items with this label are obsolete and unavailable through eCommerce.
If applicable, please view Replacement Product above or contact Hach Customer Service for further assistance.