Chemistries CLAROS                 800-227-4224

Solitax highline sc Turbidity (0.001-4000 NTU) and Suspended Solids (0.001-500 g/L) built-in probe, w/o wiper, stainless steel

Solitax highline sc Turbidity (0.001-4000 NTU) and Suspended Solids (0.001-500 g/L) built-in probe, w/o wiper, stainless steel
Product #: LXV424.99.02200
USD Price:
$6,277.00
Call for ship date
Qty in Cart:0

Certified measurements according to DIN EN ISO 7027 and DIN 38414

Turbidity measurement performance certified to MCERTS regulation and according to DIN EN ISO 7027. The Suspended solids measurement is in accordance with DIN 38414.

No calibration required

Long-term calibration stability since time-consuming multipoint calibrations with dilution series are replaced by a single correction factor.

Excellent correlation to laboratory analysis

Comparisons between laboratory analysis and continuous suspended solids measurement using SOLITAX sc sensors show an exceptional correlation to mixed liquor, settled and thickened sludge. Online measurement not only saves time on manual analysis but also provides critical real time TSS measurements that can be used to operate the plant more efficiently.

Compatible with Hach SC controller platform

Measurement data is displayed and processed with the help of a digital Hach SC200 or SC1000 controller.

For in pipe use only!

An appropriate mounting assembly for insertion application is required.

What's in the box?

Turbidity/Suspended Solids probe, user manual

Specifications

Accuracy: Turbidity up to 1000 NTU:
without calibration < 5% of the measured value ±0.01 NTU
with calibration < 1% of the measured value ±0.01 NTU
Automatic Wiper: No
Cable Length: 10 m (optional extension cables available)
Calibration Method: Turbidity: Formazin or STABLCAL Standard (at 800 NTU).
Suspended Solids: Sample specific, based on gravimetric TSS analysis with a correction factor procedure.
Certifications: CE, MCERTS
Controller: Sensor only
Diameter Sensor: 60 mm
Flow: Max. 3 m/s (the presence of air bubbles affects the measurement)
Includes: Turbidity/Suspended Solids probe, user manual
Length: 315 mm
Maintenance Interval: 1 h/month
Material: Wiper: Silicon
Sensor body: Stainless steel 1.4571
Max. cable length Sensor-to-Controller: 100 m
Measuring Principle: Infrared Duo scattered light technique for color-independent
turbidity measurement Turbidity in accordance with
DIN EN ISO 7027 / TS equivalent DIN 38414
Model: Solitax highline sc
Mounting: Insertion
Operating Temperature Range: 0 - 40 °C
Parameter: High Range Suspended Solids,
Turbidity
Pressure Range: Stainless steel insertion sensor: <6 bar or <60 m
Range: TSS-content: 0.001 - 500 g/L; 0.001 - 500,000 mg/L (the upper range is dependent on the sample property)
Turbidity: 0.001 - 4000 NTU
Repeatability: TSS content: < 3 %
Turbidity: < 1 %
Response Time T90: 1 - 300 s adjustable
Special Notes: Installation note:
Distance sensor-wall
> 50 cm (Turbidity)
Weight: Insertion stainless steel: 2.4 kg (5.29 lb.)