1920x420 Chlorine

Chlorine Analyzers, Test Kits and Reagents

Why Does Chlorine Measurement Matter?

Chlorine (Cl2) is strong oxidizing agent and ideal disinfectant. Proper residual chlorine levels in drinking water ensure that water is safe for human consumption, but too much chlorine can have detrimental effects in pharmaceutical production, membrane treatment processes and other applications.

Proper measurement and monitoring of residual chlorine levels helps to mitigate these risks. Whether you're working in a laboratory or in the field, Hach provides a variety of chlorine analyzers, sensors, reagents and more that help offer simple and reliable measurements that you can trust.

Featured Chlorine Products

Portable Chlorine Analyzers

Portable Chlorine Analyzers

Both lightweight and durable, Hach porta-ble chlorine instruments provide reliable, hassle-free, on-the-go measurement in even the most challenging conditions.

Shop Now

Online Chlorine Analyzers

Online Chlorine Analyzers

Whether you’re treating utility water, product water, or wastewater discharge, Hach’s online chlorine analyzers deliver accurate and reliable measurements of free or total residual chlorine.

Shop Now

Free and Total Chlorine Reagents

Free and Total Chlorine Reagents

Whether you’re using the DPD, amperometric or iodometric method, we offer a wide range of reagents for easy and precise chlorine measurement.

Shop Now

Chlorine Test Kits

Chlorine Test Kits

Get fast results for free or total chlorine testing with kits available for a variety of applications including drinking water and pool water.

Shop Now

Sensors and Controllers

Chlorine Sensors and Controllers

Highly adaptable to handle a variety of applications and parameters, Hach sensors and controllers ensure accurate and efficient chlorine measurement

Shop Now

Why Measure Chlorine?

When added to water, chlorine reacts to form free chlorine or chloramines (when ammonia is present), which:

However, excess residual chlorine can have a variety of risk including the following:

Risks Associated with the Presence of Residual Chlorine

Dechlorination Methods

Since chlorine can be detrimental, there are applications that require "dechlorination." Adsorption dechlorination uses activated carbon to remove chlorine compounds. Chemical dechlorination uses reducing agents such as sulfites, bisulfites or metabisulfites to destroy chlorine species.

Which Processes Require the Monitoring of Chlorine?

During pre-oxidation, source water entering a plant is dosed with chlorine (pre-chlorination) to precipitate out minerals as a primary treatment step (besides disinfection) to help with suspended and dissolved matter removal before filtration. The water is then filtered to improve clarity and chlorinated again.

For chlorine to be effective, its concentration before and after filtration (as well as pH, water temperature, and contact time) must be monitored and controlled. Most treatment plants have a contact chamber (clear well) where chlorine is injected, mixed and allowed to remain in contact with the water for the required time dependent on the temperature, pH and type of microorganisms present in the water. The contact time provides a chlorine residual, intended to maintain water sanitized as it enters storage tanks and travels throughout the distribution system.

All chlorination before (pre-chlorination) and after filters (post-chlorination) is controlled at multiple points throughout the treatment process and in the distribution system. Additional booster chlorination of tap water in the network is usually conducted at pump/booster stations and must be thoroughly monitored and controlled.

It is essential to monitor chlorine levels in the distribution system to ensure that the proper level of chlorine residual is maintained to meet regulatory standards for disinfection, and to ensure that there is no excessive chlorine present.

Advantages of Using Chlorine to Disinfect Drinking Water

  • Chlorine eliminates slime bacteria, molds and algae that commonly grow in water supply reservoirs, on the walls of water mains, and in storage tanks.
  • Chlorine is a potent germicide, reducing the level of many disease-causing microorganisms in drinking water to regulatory appropriate levels.
  • Chlorine helps remove dissolved iron and manganese from raw water.
  • Chlorine reduces many disagreeable tastes and odors by:
    • oxidizing natural organics such a foul-smelling algae secretion, sulfides, and odors from decaying vegetations.
    • destroying hydrogen sulfide, which has a rotten egg smell.
    • removing ammonia and other nitrogenous compounds that may cause unpleasant tastes.

Disadvantages of Using Chlorine to Disinfect Drinking Water

  • Chlorine is not effective against cryptosporidium, a life-threatening parasite.
  • During chlorination, unwanted ammonia can react with chlorine excess to form chloramines that lower the disinfection potential and may create taste/odor issues when not monitored and controlled efficiently.
  • When reacting with organics in water, chlorine can form disinfection by-products (DBP) that are considered harmful to human health. Due to these risks, there are regulations that limit levels of DBP as well as chlorine residual concentrations in drinking water.

Shop Now

An aerial view of a drinking water treatment plant. Chlorine is used to disinfectant.

How is Chlorine Monitored?

Hach CL17sc Chlorine Analyzer

Colorimetry

In general, this optical method uses color intensity measurements to determine the concentration of chlorine in a solution. When appropriate buffer and indicator solutions are added to the sample, a reaction occurs producing a color, which intensity is proportional to the chlorine concentration. The color intensity is measured by eye, colorimeter or spectrophotometer. This method is susceptible to interference from color and turbidity in the sample, as well as some chemical substances besides chlorine, concurrently reacting with the indicator.

DPD Method

DPD method is the most widely used colorimetric method to measure chlorine. It can be used to measure both free and total chlorine with field, lab and online instrumentation. However, DPD method is subject to interference from other oxidants such as manganese, chromium and chloramines.

Indophenol Method

Indophenol method, being selective to monochloramine, can be used to measure monochloramine and free ammonia as well as free chlorine. Monochloramine is determined directly, while for determination of both monochloramine and free ammonia in the same sample method uses additional reagent to convert free ammonia into monochloramine. Free chlorine can also be measured by the indophenol method using a two-reagent system that is not subject to the interferences that affect the DPD method. However, this method is only available for the laboratory or field analyses and not for online analyzers.

Hach Titration Application Pack Amperometric: Free & Total Chlorine, Chlorine Dioxide, Chlorite, & Sulfite (Autocat)

Titration

This method determines chlorine concentration based on a completion of chemical reaction between the chlorine and titrant added to the sample. The titrant is added incrementally until the reaction is complete. The endpoint (or equivalence point) is the point at which the titrant and chlorine are balanced. The equivalence point can be determined visually using a color indicator or by using an electrochemical sensor. Manual, visual measurements are less precise and more susceptible to interference from color or turbidity in the sample, while titration using electrodes is more accurate and not susceptible to those interferences.

DPD-FEAS Method

DPD-FEAS method uses a magenta visual indicator that is titrated to a colorless endpoint. This method measures free and total chlorine.

Iodometric Method

Iodometric method uses a blue visual indicator that disappears at the titration endpoint. This method is typically used to measure high concentrations of total chlorine.

Amperometric

This method represents amperometric titration to determine the endpoint either manually, or automatically. A small voltage is applied to the electrode and the endpoint is determined by a change in current, resulting from the reduction of chlorine by the titrant (phenylarsine oxide). The change in current and the volume of titrant are measured to correspond to the concentration of the chlorine. This method offers procedures for measuring both free and total chlorine, chlorine dioxide and chlorite, while using forward and back titration procedures.

Hach CL10sc Amperometric Chlorine Analyzer 

Online Amperometry

This electrochemical method measures the change in electrical current resulting from chemical reactions taking place at the electrodes, with the current being proportional to the chlorine concentration. Different amperometric sensor designs are available, providing better selectivity for different chlorine species. This method is not susceptible to interference from color or turbidity in the sample, however, the sensor surface exposed to the sample is prone to fouling. Some amperometric analyzers do not require reagents. Amperometric sensors require maintenance and must be calibrated in-situ at a frequency dependent on the application.

Frequently Asked Questions

View Products and Services

Your selection

  • Chlorine
  • Chlorine Demand / Requirement
  • Chlorine-Free

Market Class

Parameter

Product Type

Product Sub-Type

Application

Topic

Topic Detail

Method/Technology

Method Number

Location

Industry

DR900 Colorimeter
9385100
$2,258.00
WarrantyPlus® Partnership, Ultra Low Range CL17sc, 2 Services/Year
WRTUPGULRCL17
Price: Contact Us
WarrantyPlus® Partnership, SC1500, 1 Service/Year
WRTUPGSC1500
$341.00
WarrantyPlus® Partnership, CL17sc, 2 Services/Year
WRTUPGCL17SC
Price: Contact Us
WarrantyPlus® Partnership, 9184sc, 2 Services/Year
WRTUPG9184
Price: Contact Us
Loading