9245 Single Channel Online Sodium Analyzer (0 to 10,000 ppb) with Enclosure, Universal

9245 Single Channel Online Sodium Analyzer (0 to 10,000 ppb) with Enclosure, Universal

Product Number: 6849400

Obsolete

Hazardous Materials

Hazardous shipping. Items with this mark may be considered hazardous under some shipping conditions. If necessary, we will change your selected shipping method to accommodate these items.

Sodium monitoring for high purity waters

The 9245 Sodium Analyzer is a single channel online analyzer with a detection limit of 0.01 ppb and a measuring range of 0-10,000 ppb. To maintain optimum response time, even in systems of continuous low sodium concentration, the analyzer automatically reactivates the electrode using non-hazardous chemicals. This sodium analyzer is easy to install; it requires only power and sample connections. Four sets of isolated analog outputs can be configured in 4-20 mA outputs and one reporting electrode live signal including calibration and grab sample.


Benefits

Automatic Electrode Reactivation for Optimum Operation and Response Time

To maintain optimum response time, even in systems of continuous low sodium concentration, the analyzer automatically reactivates the electrode using non-hazardous chemicals.

Easy to Install, Operate, Calibrate, and Maintain

The 9245 Sodium Analyzer installs easily; it requires only power and sample connections. Clear step-by-step instructions are given by the analyzer to simplify operations such as instrument start-up, long-term stand-by, and reagent replenishment. Low ppb sodium solutions for calibration can be difficult to prepare so the 9245 analyzer is equipped with a fully automated calibration system that uses 10 ppm samples and follows a multiple step calibration cycle to accurately calibrate the analyzer. Normal maintenance consists of replenishment of the calibration solution reagents and electrolyte, typically every 100 days, and annual replacement of the reagent tube.

Adaptable to a Variety of Conditions

The analyzer is fitted with a quick-loop valve, a constant head vessel, and minimum sample flow detection to allow for variations in sample pressure, flow, and distance from the analyzer to the fresh-sample point. Grab sample can be obtained for manual calibration, accuracy verification, and measurement of one-off process samples after which, the unit returns automatically to on-line monitoring.

Lower Detection Limit of 0.01 ppb

With a detection limit of 0.01 ppb and a range of 0 to 10,000 ppb, the 9245 Sodium Analyzer is ideally suited for monitoring sodium in demineralized water, boiler feed, condensate, and all parts of the steam/water cycle.

4-20 mA Outputs and Digital Communication Options

Four sets of isolated analog outputs can be configured in 4-20 mA with three outputs assigned to sample concentration or temperature readings and the fourth reporting electrode live signal, including calibration and grab sample. Additional digital communication is available with JBUS/MODBUS or Profibus DP.

Alarms and Diagnostics

Two programmable alarm relays may be assigned to concentration limits, delay, hysteresis, normal relay status, minimum sample flow rate detection, or operation of the measurement cycle for a channel. Two additional programmable relays may be used for warning messages (reagent level low, small calibration deviation, and system alarms (no reagents, no sample, no calibration, no power supply).

Loading

Videos

Label Definitions*


Product Life Cycle

*when applicable

Phase Out

Items with this label are at the end of their life cycle and may become obsolete in the future.

Obsolete

Items with this label are obsolete and unavailable through eCommerce.
If applicable, please view Replacement Product above or contact Hach Customer Service for further assistance.