| 1. |
Barcode Recognition Eliminate human error with automatic method and wavelength detection. |
| 2. |
Reference Detector Monitors and compensates for optical fluctuations. |
| 3. |
10X Measurement and Outlier Elimination As the vial rotates, any scratches, soil, and flaws on the glass are detected— and these measurement outliers are rejected. |
TNTplus works only with the following spectrophotometers:
| Description |
|
|
|
|
Prod. # |
| DR 5000 UV-Vis Spectrophotometer |
DR5000-03 |
| DR 3800 Portable Spectrophotometer |
DR3800-01 |
| DR 2800 Portable Spectrophotometer |
DR2800-01 |
 |
| Description |
Range (mg/L) |
EPA |
Digestion Required |
#Tests |
Prod. # |
| Alkalinity, Total |
25-400 mg/L CaCO3 |
|
|
25 |
TNT870 |
Aluminum TNTplus, Chromazurol S Method |
0.02-0.50 Al |
|
|
24 |
TNT848 |
| Ammonia TNTplus, ULR |
0.015-2.00 NH3-N |
Yes |
|
25 |
TNT830 |
| Ammonia TNTplus, LR |
1-12 NH3-N |
Yes |
|
25 |
TNT831 |
| Ammonia TNTplus, HR |
2-47 NH3-N |
Yes |
|
25 |
TNT832 |
Cadmium TNTplus*†, Cadion Method |
0.02-0.30 Cd |
|
|
25 |
TNT852 |
Chromium, Hexavalent and Total TNTplus |
0.03-1.00 Cr |
Yes‡ |
|
25 |
TNT854 |
| COD TNTplus, ULR |
1-60 COD |
|
Yes |
24 |
TNT820 |
| COD TNTplus, LR |
3-150 COD |
Yes |
Yes |
25 |
TNT821 |
| COD TNTplus, LR |
3-150 COD |
Yes |
Yes |
150 |
TNT82106 |
| COD TNTplus, HR |
20-1,500 COD |
Yes |
Yes |
25 |
TNT822 |
| COD TNTplus, HR |
20-1,500 COD |
Yes |
Yes |
150 |
TNT82206 |
| COD TNTplus, UHR |
250-15,000 COD |
|
Yes |
25 |
TNT823 |
| COD TNTplus, HR, Hg-Free |
25-1,000 COD |
|
Yes |
25 |
TNT825 |
| Copper TNTplus* |
0.1-8.0 Cu |
|
|
25 |
TNT860 |
| Chlorine, Free TNTplus |
0.05-2.00 Cl2 |
Yes |
|
39 |
TNT866 |
| Chlorine, Free & Total TNTplus |
0.05-2.00 Cl2 |
Yes |
|
39 |
TNT866T |
| Iron TNTplus* |
0.2-6.0 Fe |
Yes |
|
25 |
TNT858 |
| Lead TNTplus*, PAR Method |
0.1-2.0 Pb |
|
|
25 |
TNT850 |
| Nickel TNTplus*, Dimethylglyoxime Method |
0.1-6.0 Ni |
|
|
25 |
TNT856 |
| Nitrate, Nitrogen TNTplus, LR |
0.23-13.50 NO3--N |
|
|
25 |
TNT835 |
| Nitrate, Nitrogen TNTplus, HR |
5-35 NO3--N |
|
|
25 |
TNT836 |
| Nitrite, LR TNTplus |
0.015-0.600 NO2--N |
Yes |
|
25 |
TNT839 |
| Nitrite, HR TNTplus |
0.6-6.0 NO2--N
(2.0-20.0 NO2-) |
|
|
25 |
TNT840 |
| Nitrogen, Simplified Total Kjeldahl |
0-16 N |
|
Yes |
25 |
TNT880 |
| Nitrogen, Total TNTplus, LR |
1-16 N |
|
Yes |
25 |
TNT826 |
| Nitrogen, Total TNTplus, HR |
5-40 N |
|
Yes |
25 |
TNT827 |
| Nitrogen, Total TNTplus, UHR |
20-100 N |
|
Yes |
25 |
TNT828 |
| Phosphorus, Reactive TNTplus |
1.6-30 P (5.0 - 90.0 PO4) |
|
|
25 |
TNT846 |
| Phosphorus, Reactive and Total TNTplus, LR |
0.05-1.5 P (0.15-4.5 PO4) |
Yes |
Yes for Total |
25 |
TNT843 |
| Phosphorus, Reactive and Total TNTplus, HR |
0.5-5.0 P (1.5-15.0 PO4) |
Yes |
Yes for Total |
25 |
TNT844 |
| Phosphorus, Reactive and Total TNTplus, UHR |
2-20 P (6-60 PO4) |
Yes |
Yes for Total |
25 |
TNT845 |
| Sulfate TNTplus, LR |
40-150 SO4 |
|
|
25 |
TNT864 |
| Sulfate TNTplus, HR |
150-900 SO4 |
|
|
25 |
TNT865 |
| Volatile Acids |
50-2500 mg/L CH3COOH (acetic acid) |
|
Yes |
25 |
TNT872 |
|
| • |
Barcoded Vials —
When used with the DR 5000 and DR 2800, the instrument automatically reads the barcode, identifies the appropriate method, and takes the measurement — eliminating error and saving time. |
| • |
Color-coded Vials and Packaging —
TNTplus vial chemistry packages are color-coded for fast and easy parameter recognition. Step-by-step illustrated test methods are printed on the box for quick reference. |
| • |
Innovative Reagent Delivery —
TNTplus reagents requiring additional reagents use DosiCaps, easier to use than powder pillows or liquid reagents. Because the additional reagents are completely contained in the vial cap, DosiCaps reduce the risk of spillage and contamination. |
| • |
New Packaging —
Smaller, environmentally friendly, and includes both simple and detailed procedures.
|
|