SC4500 Sensor Compatibility

The SC4500 is compatible with a wide range of sensors and analyzers. Legacy Hach® sensors must meet a minimum software requirement in order to function with the SC4500.

Use the search function or scroll down for details.


Sensor/AnalyzerSupported Software
Version
Release
Year
NotesImage
1200-S sc v1Not supportedNot supportedSerial number label will clearly state "V1"1200-S sc Digital pH sensor for SC controller
1200-S sc v2V2.04 or higher2013Serial number label will clearly state "V2"1200-S sc V2 Digital pH sensor for SC controller
1720E scV2.10 or higher20061720E sc
3400 Conductivity: Analog 34xx sc + Contacting Conductive Digital Gateway 6120700Not supportedNot supported 3400 v1
3400 v2V3.00 or higher20163400 v2
3700 Conductivity: Analog 37xx sc + Inductive Conductive Digital Gateway 6120800V3.00 or higher2017

3700 Conductivity: Analog 37xx sc + Inductive Conductive Digital Gateway 6120800

3700 Conductivity: Analog 37xx sc + Inductive Conductive Digital Gateway 6120800

3700 v1Not supportedNot supported  3798 sc v2
3400 and 3700 Analog Conductivity + SC4500 Conductivity module LXZ525.99.D0004
3798 sc v2V2.03 or higher2013Serial number label will clearly state "V2"3798 sc v2
3798 sc v1Not supportedNot supportedSerial number label will clearly state "V1"3798 sc v2
5500 (Analog)Not supportedNot supported 
8362 sc panel Ultrapure pH/ORPV3.00 or higher2017 8362 sc panel Ultrapure pH/ORP
8362 sc v1Not supportedNot supported  
91xx sc v1Not supportedNot supportedSerial number label will clearly state "V1" 
91xx sc v2V2.03 or higher2013Serial number label will clearly state "V2"91xx sc v2
A-ISE scV1.02 or higher2016 A-ISE sc
Amtax scV2.30 or higher2018 Amtax sc
AN-ISE scV1.08 or higher2013 AN-ISE sc
CL10 scV1.14 or higher2013 CL10 sc
CL17 scV2.70 or higher2019 

CL17 sc

CL17 sc

FP360Supported
 

FP360sc Oil-in-Water Sensor, 500 ppb, Stainless Steel Body, 10 m (32.8 ft) Cable, with Cleaning Unit

FP360 scV1
GLI 3400 analog with SC4500 conductivity moduleSupported

Contacting Conductivity Sensor, Mid-Range Conductivity (k=1.0), with ¾" PVDF Compression Fitting
GLI 3700 analog with SC4500 conductivity moduleSupported
 3700 Inductive Conductivity Sensor, Convertible, PVDF Body Material
LDO v1Not supportedNot supported  
LDO2 scV1.22 or higher2013 LDO2 sc
NH4D scNot supportedNot supported  
N-ISE scV1.02 or higher2016 N-ISE sc
NitraTax scV3.13 or higher2013 NitraTax sc
NT3SupportedNT3100sc UV Nitrate Sensor, 1 mm path length
Nitro scSupported
pHD sc v2V3.10 or higher2016 pHD sc v2
pHD v1Not supportedNot supported  
pHD and LCP (Analog) + pH/ORP Digital Gateway 6120500
pHD, pH combination and LCP (Analog) + SC4500 pH/ORP module LXZ525.99.D0003Supported 
Hach pHD Online Process pH Sensor - General Purpose pH Sensor
Phosphax LR scV1.01 or higher2018 Phosphax LR sc
Phosphax MR scV2.30 or higher2018 Phosphax MR sc
RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600V3.00 or higher2017 RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600
SOLITAX scV2.20 or higher2013 SOLITAX sc
Sonatax scV1.15 or higher2016 Sonatax sc
SS7 scV1.06 or higher2006 SS7 sc
TSS scV41.73 or higher2013 TSS sc
TU5300 sc
TU5400 sc
V1.34 or higher2017 TU5300/TU5400 sc
ULR CL17scSupported
Ultraturb scV3.06 or higher2017 Ultraturb sc
UVAS Plus scV3.01 or higher2017 UVAS Plus sc