The SC4500 is compatible with a wide range of sensors and analyzers. Legacy Hach® sensors must meet a minimum software requirement in order to function with the SC4500.
Use the search function or scroll down for details.
Sensor/Analyzer | Supported Software Version | Release Year | Notes | Image |
---|---|---|---|---|
1200-S sc v1 | Not supported | Not supported | Serial number label will clearly state "V1" | |
1200-S sc v2 | V2.04 or higher | 2013 | Serial number label will clearly state "V2" | |
1720E sc | V2.10 or higher | 2006 | ||
3400 Conductivity: Analog 34xx sc + Contacting Conductive Digital Gateway 6120700 | Not supported | Not supported | ||
3400 v2 | V3.00 or higher | 2016 | ||
3700 Conductivity: Analog 37xx sc + Inductive Conductive Digital Gateway 6120800 | V3.00 or higher | 2017 | ||
3700 v1 | Not supported | Not supported | ||
3400 and 3700 Analog Conductivity + SC4500 Conductivity module LXZ525.99.D0004 | ||||
3798 sc v2 | V2.03 or higher | 2013 | Serial number label will clearly state "V2" | |
3798 sc v1 | Not supported | Not supported | Serial number label will clearly state "V1" | |
5500 (Analog) | Not supported | Not supported | ||
8362 sc panel Ultrapure pH/ORP | V3.00 or higher | 2017 | ||
8362 sc v1 | Not supported | Not supported | ||
91xx sc v1 | Not supported | Not supported | Serial number label will clearly state "V1" | |
91xx sc v2 | V2.03 or higher | 2013 | Serial number label will clearly state "V2" | |
A-ISE sc | V1.02 or higher | 2016 | ||
Amtax sc | V2.30 or higher | 2018 | ||
AN-ISE sc | V1.08 or higher | 2013 | ||
CL10 sc | V1.14 or higher | 2013 | ||
CL17 sc | V2.70 or higher | 2019 | ||
FP360 | Supported | |||
FP360 sc | V1 | |||
GLI 3400 analog with SC4500 conductivity module | Supported | |||
GLI 3700 analog with SC4500 conductivity module | Supported | |||
LDO v1 | Not supported | Not supported | ||
LDO2 sc | V1.22 or higher | 2013 | ||
NH4D sc | Not supported | Not supported | ||
N-ISE sc | V1.02 or higher | 2016 | ||
NitraTax sc | V3.13 or higher | 2013 | ||
NT3 | Supported | |||
Nitro sc | Supported | |||
pHD sc v2 | V3.10 or higher | 2016 | ||
pHD v1 | Not supported | Not supported | ||
pHD and LCP (Analog) + pH/ORP Digital Gateway 6120500 | ||||
pHD, pH combination and LCP (Analog) + SC4500 pH/ORP module LXZ525.99.D0003 | Supported | |||
Phosphax LR sc | V1.01 or higher | 2018 | ||
Phosphax MR sc | V2.30 or higher | 2018 | ||
RC and PC analog sensor + Digital Gateway for conventional analog pH and ORP sensors 6120600 | V3.00 or higher | 2017 | ||
SOLITAX sc | V2.20 or higher | 2013 | ||
Sonatax sc | V1.15 or higher | 2016 | ||
SS7 sc | V1.06 or higher | 2006 | ||
TSS sc | V41.73 or higher | 2013 | ||
TU5300 sc TU5400 sc | V1.34 or higher | 2017 | ||
ULR CL17sc | Supported | |||
Ultraturb sc | V3.06 or higher | 2017 | ||
UVAS Plus sc | V3.01 or higher | 2017 |